M710

NEC Storage M710

 

3.5" Disk Array Unit/Disk Enclosure Unit

 

Modular design - each module holds 12 drives

 

2.5" Disk Array Unit/Disk Enclosure Unit

 

Modular design - each module holds 24 drives

Model Name


M710
Units Unit Types Disk Array Controller
Disk Enclosure (2.5" & 3.5")
Number of Disk Enclosures (Max.) 80
Number of Drive Slots in Total (Max.) *1 960
Number of Drive Slots per Enclosure Disk Enclosure (2.5"): 24
Disk Enclosure (3.5"): 12
Host Interface FC (8Gbps/16Gbps): Max 48 ports
iSCSI (10Gbps): Max 24 ports
Drive Interface
(Interface between DAC & DE, or between DE's *2)
SAS3.0 (12Gbps)
Cache Memory Capacity 96GB or 192GB
Backup Method Save to a dedicated area
RAID Level *3,*4 RAID-0, 1, 5, 6, 10, 50, 60, TM
Number of Drives *1 3 to 960
Drive Types SAS HDD 2.5": 600GB,1.2TB,1.8TB(10,000rpm) / 300GB,600GB(15,000rpm)
3.5": 300GB(15,000rpm)
Nearline SAS HDD 2.5": 1TB,2TB(7,200rpm)
3.5": 2TB,4TB,6TB,8TBNew spec(7,200rpm)
SAS SSD 2.5": 200GB,400GB,1.6TB,3.84TBNew spec
3.5": 200GB,400GB,1.6TB,3.84TBNew spec
SED SAS HDD *5
2.5": 600GB(10,000rpm) / 600GB(15,000rpm)
SED Nearline SAS HDD *5
3.5": 4TB(7,200rpm)
SED SAS SSD *5
2.5": 200GB
3.5": 200GB
Max. Storage Capacity *6 SAS HDD 2.5": 1360.5TB
3.5": 221.2TB
Nearline SAS HDD 2.5": 1517.1TB
3.5": 6066.3TBNew spec
SAS SSD 2.5": 2651.7TBNew spec
3.5": 2651.7TBNew spec
SED SAS HDD *5
2.5": 445.1TB
SED Nearline SAS HDD *5
3.5": 3033.0TB
SED SAS SSD *5
2.5": 132.4TB
3.5": 132.4TB
Chassis Dimensions (Width x Depth x Height) Disk Array Controller (Rack Unit)
482.0 x 633.8 x 175.4 mm (4U, w/o Front Bezel)
482.0 x 643.8 x 175.4 mm (4U, w/ Front Bezel) *7
Disk Enclosure (Rack Unit)
482.0 x 548.5 x 87.4 mm (2U, w/o Front Bezel)
482.0 x 558.5 x 87.4 mm (2U, w/ Front Bezel) *7
Weight Disk Array Controller 48kg or less
Disk Enclosure 2.5" 26kg or less
3.5" 29kg or less
Power Voltage, Frequency, Phase AC100 - 240V, 50/60Hz, Single phase
Power Consumption(Max. / @25 deg.C) Disk Array Controller *8 1,190W(1,200VA) / 1,065W
Disk Enclosure 350W(350VA) / 285W (SAS HDD)
315W(320VA) / 250W (Nearline SAS HDD)
Temperature Operating: 5 to 40 degrees Celsius
Non-operating: -10 to 60 degrees Celsius
Relative Humidity Operating: 10 to 80%RH
Non-operating: 5 to 80%RH
Supported OS *9 FC: Windows, Linux, VMware, HP-UX, AIX, Solaris
iSCSI: Windows, Linux, VMware
  • *1: Host ports and drive slots are added exclusively.
  • *2: DAC stands for Disk Array Controller, DE stands for Disk Enclosure.
  • *3: It is not recommended to use RAID-0, which has a risk of data loss in case of one drive error.
  • *4: The RAID levels available for SSD are RAID-1, 5, 6, 10, 50, and 60.
  • *5: SED stands for Self-Encrypting Drive.
  • *6: TB represents 1,024^4B.
  • *7: The Front Bezel is sold separately.
  • *8: Host interface is FC.

*9: Please contact NEC for possible restrictions.